Faults
Fault or fault combination
#Fault code
P0243
boost pressure - solenoid interruption
|
P0340
Cam shaft sensor no/ faulty signal
|
P0606
engine control unit
|
Other faults on request |
Important repair hints (!)
Disassembly instructions: Please only remove the control unit.
Cut the cables to the solenoid valves in such a way that their assembly is possible after the repair with suitable solder or press connectors. After loosening the fastening screws, carefully lift the control unit so as not to tear off the ribbon cable located on the underside of the PSG. Unscrew the rotation angle sensor located in the pump and fix it with the ribbon cable to the pump control unit using suitable means (e.g. cable ties).